What Are Fire-Rated Metal Deck Options for Commercial Builds?

Commercial fire ratings come from listed assemblies, not from the deck alone. Composite floor deck with the specified concrete topping, and roof deck with the listed insulation, fireproofing or ceiling, are used in tested designs. Your architect selects the design number, and the deck profile and gauge must match it. We supply the deck that listing requires.

How Assemblies Are Rated

Testing laboratories such as UL list floor-ceiling and roof-ceiling designs with an hourly rating. Each design states the permitted deck types, minimum concrete thickness and type, and any spray fireproofing or protective ceiling. Restrained or unrestrained classification also matters.

We do not claim a fire rating for our deck itself. Confirm the specific design number and that the deck you order conforms to it.

Typical Approaches

Ask us for the product data your submittal needs, and send the plans with the design numbers for a quote.

  • Floors: composite deck with a concrete slab sized to the listing
  • Roofs: deck with listed insulation, membrane and fireproofing or ceiling
  • Steel members: spray fireproofing where the design requires it
  • Exposed deck ceilings: verify the listing permits unprotected deck

Related Questions

Does a heavier gauge deck increase the fire rating?

Not by itself. Ratings depend on the tested assembly. Some listings set a minimum gauge or specific profiles, but slab thickness, concrete type and fireproofing usually govern. Check the design number your architect specifies. We supply the gauge the listed design and structural drawings require.

Who decides which fire-rated design to use?

The architect selects the design based on the required rating, construction type and occupancy under the building code. The structural engineer confirms the deck and slab work with it. We supply the deck the drawings call for. Ask us for the product data your submittal needs.