When Do Stadiums Need Heavy-Gauge Composite Deck?
Stadiums, arenas and public buildings often use 18 or 16 gauge composite deck, usually in 2" or 3" profiles, because concourses and suites carry heavy assembly loads, long spans and large diaphragm forces. The engineer of record sets the gauge. Our composite deck comes in 1.5", 2" and 3" profiles, 22 to 16 gauge, 50 ksi, G60 or G90.
Why Public Venues Push Gauge Up
- Assembly occupancy live loads on concourses and seating areas
- Long beam spacing in open spaces
- Heavy equipment, kitchens and mechanical rooms
- Diaphragm forces for wind and seismic in large footprints
- Hanging loads for ceilings, signage and MEP; hanger tabs on 20ga and heavier
Planning a Large Venue Order
Venues mix gauges by area, so the takeoff and shop drawings must track each zone. Order pour stop and accessories with the deck, and plan releases around the erection sequence and crane picks.
Send the structural set and we will prepare a zone-by-zone takeoff and quote.
Composite floor deck (1.5", 2" and 3"), 50 ksi: catalog design thickness and weight
| Gauge | Design thickness (in) | Deck weight (psf) | Hanger tabs |
|---|---|---|---|
| 22 | 0.0295 | 1.7 | Not available |
| 20 | 0.0358 | 2.1 | Available |
| 18 | 0.0474 | 2.7 | Available |
| 16 | 0.0598 | 3.4 | Available |
Related Questions
Is 16 gauge the heaviest composite deck you carry?
In the current catalog, composite floor deck runs 22 to 16 gauge. If your design calls for something outside that range, send the specification and we will tell you what we can supply. Hanger tabs are available on 20ga and heavier composite deck.
Do exposed concourse ceilings need special deck?