SDI Member · ANSI/SDI compliant
Metal roof deck supplier in Hialeah
We supply certified (SDI) metal roof decks in Hialeah to support high-rise, hospitality, and industrial roof structural needs.

Local Metal Roof Decks supply for Hialeah
General contractors and steel erectors in Hialeah rely on Miami Metal Deck for Metal Roof Decks on projects across Miami-Dade County and the South Florida region. Hialeah is close to our Miami Gardens facility, so stock items are available for same-day pickup and same-day delivery within South Florida.
With Hialeah's coastal humidity and salt air, many engineers specify a G90 galvanized finish for its heavier zinc coating; we confirm the finish against your project specifications. Miami-Dade County falls within the Florida Building Code's High-Velocity Hurricane Zone (HVHZ). Send us the deck and attachment requirements on your drawings so we can supply the specified gauge and lengths.
Product guide
Product specifications for your Hialeah project
Compare profiles, dimensions, material options and applications to prepare your order. Select a product below to explore its technical details.
1.5" Type B Roof Deck
Looking for a 1.5" Type B metal deck supplier for projects in Hialeah? This roof deck delivers strong structural performance and goes in quickly. It comes in 22 GA to 16 GA, meets SDI and ANSI standards, and ships in galvanized finishes such as G60 and G90 for added durability and corrosion resistance on Hialeah roofing jobs.
Dimensions and profile

| Property | Dimension |
|---|---|
| Profile Depth | 1.5 inches |
| Coverage Width | 36 inches |
| Rib Spacing | 6 inches (center to center) |
| Rib Height | 1.5 inches |
This 1.5" Type B metal deck has a 1.5 inch rib depth and a standard coverage width of 36 inches, which makes it structurally efficient for roofing and flooring. Ribs sit 6 inches apart (center to center), and the 39 inch overall material width gives secure overlaps and strong composite action with concrete slabs. The profile maximizes strength at minimal weight, so it works across many kinds of construction.
Gauges and thicknesses
| Gauge | Bare steel thickness (in) | Weight (lbs/sq ft) | Typical applications |
|---|---|---|---|
| 22 | 0.0295 | 1.6 | Light-duty roofing and small spans. |
| 20 | 0.0358 | 2 | Medium spans, roofing, and siding. |
| 18 | 0.0474 | 2.6 | Heavy-duty applications. |
| 16 | 0.0598 | 3 | Heavy load spans. |
There are four gauges to choose from for Type B deck: 22, 20, 18, and 16. Each has different thickness and load capacity, so you can fit the deck to the project. Light and cost-effective, 22 and 20 gauge are best on shorter spans and lighter loads. Stronger 18 and 16 gauge carry longer spans and heavier loads, which makes them ideal for demanding applications.
Finishes and coatings
| Finish | Details |
|---|---|
| Galvanized G60 | Zinc coating of 0.6 oz/ft². Recommended for general environments. |
| Galvanized G90 | Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments. |
| Prime-Painted | Provides a base coat for additional protection or paint adhesion. |
| Bare Steel | Unfinished; typically for indoor use or controlled environments. |
For lasting performance, Type B deck is offered with galvanized (G60 and G90) and prime-painted finishes, among others. Galvanizing gives excellent corrosion resistance, and G90 has the higher zinc coating for environments with more exposure to moisture or chemicals. If the project needs extra paint or coating layers, the prime-painted option supplies a protective base coat.
Material and finish options
Steel is offered in 33 KSI, 40 KSI, 50 KSI, and 80 KSI grades, each engineered for a particular structural demand and balancing strength against flexibility. Both galvanized (G60/G90) and prime-painted finishes conform to ASTM A653 for corrosion resistance.
Custom lengths
Deck lengths start at 6′-0″ for compact jobs and run up to 40′-0″ for large structures, so we can fit nearly any layout in Hialeah. Cutting to your custom length keeps waste low and the deck fitting properly on site.
1.5" Type B Roof Deck features
Lightweight yet durable, our 1.5" Type B metal deck also brings fire resistance and a sustainable design. It is a practical, eco-friendly pick for short-span commercial projects.
High Strength-to-Weight Ratio
Exceptional load capacity at low weight suits roofing systems well.
Standard 36 inches Coverage
Coverage is 36 inches wide with a consistent rib design, so installation takes less time and runs more efficiently.
Galvanized or Prime-Painted Finish
Galvanized G60/G90 or prime-painted: either finish improves durability and resists corrosion.
Compatibility with Roofing Systems
Fits roofing systems that use insulation, waterproofing, reflective coatings, drainage, ventilation, and other components.
Compliance with Standards
Steel Deck Institute (SDI) and ANSI guidelines are met, which assures quality and code compliance.
Wide Gauge Range
Choose 22, 20, 18, or 16 gauge to customize the deck for specific load-bearing requirements and project demands.
Installation and connections
Installation practices
- Place the deck perpendicular to the supports.
- Secure the deck to each support using puddle welds or TEK screws.
- Overlap the sidelaps, then screw them down at 12" o.c.
Fasteners and attachments
- 5/8" Diameter Puddle Welds
- #10 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
- Sidelaps attached using #10 TEK screws at 12" o.c.
Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.
Applications

Roof Deck Applications
Commercial and industrial roof systems that demand structural strength and durability rely heavily on Type B. It carries roofing insulation systems and works for vented as well as non-vented roofs.

Hybrid Structural-Ceiling Systems
Type B can also serve as an exposed ceiling in architectural spaces. It gives structural strength and a clean look while trimming extra materials and installation time.
Standards and product documentation
For Hialeah contractors, the 1.5" Type B deck complies with SDI (Steel Deck Institute) specifications, supporting high standards of design and performance.
1.5" Type B Roof Deck questions
Which gauge is used most often for Type B decking?
Most projects use 20 gauge, since it balances cost and strength for typical applications. Specific project requirements may call for a different gauge.
How do G60 and G90 galvanized finishes differ?
G60 has a 0.60 oz/ft² coating and G90 has 0.90 oz/ft², which is 50% more zinc and better corrosion resistance. G60 fits indoor use or low-moisture settings. G90 is the choice for outdoor use, roofing, steel decking, and structures exposed to weather, humidity, or corrosive conditions.
How far can the 1.5" Type B deck span?
Gauge, span type, and load requirements all affect maximum span. As an example, 22-gauge deck can span up to 8 feet over multiple spans, and 16-gauge deck can reach up to 14 feet. Check the load tables for exact values.
Can 1.5" Type B metal deck be customized for a project in Hialeah?
Yes. Gauge, finish, and length can all be customized. Custom lengths are cut to the project, which cuts waste and makes installation more efficient.
Is 1.5" Type B metal deck compliant with industry standards?
Yes. It follows Steel Deck Institute (SDI) standards and American Iron and Steel Institute (AISI) design guidelines, which supports quality, safety, and compatibility with building codes.
3" Type N Roof Deck
Because of its long-span capability and structural strength, 3" Type N metal deck is widely specified for roofs. The Type N profile is 3 inches deep, with gauges from 22 GA to 16 GA for flexibility on roofing projects in Hialeah. It complies with SDI and ANSI standards and is offered in galvanized finishes such as G60 and G90.
Dimensions and profile

| Property | Dimension |
|---|---|
| Profile Depth | 3 inches |
| Coverage Width | 24 inches |
| Rib Spacing | 8 inches (center to center) |
| Rib Height | 3 inches |
Depth of profile is 3 inches and coverage width is 24 inches on the Type N Roof Deck. Rib spacing measures 8 inches (center to center), and rib height is 3 inches. A deep rib like this gives the strength needed for longer spans and heavy roofing loads, and the wide coverage makes large roofs quicker to cover.
Gauges and thicknesses
| Gauge | Bare steel thickness (in) | Weight (lbs/sq ft) | Typical applications |
|---|---|---|---|
| 22 | 0.0295 | 1.8 | Light duty roofs. |
| 20 | 0.0358 | 2.2 | Standard commercial roofs. |
| 18 | 0.0474 | 2.9 | Heavy load areas. |
| 16 | 0.0598 | 3.7 | Long spans, high loads. |
The Type N Roof Deck comes in 22, 20, 18, and 16 gauge, with different thicknesses and load capacities for each roofing project. Lighter gauges (22 and 20) cost less and suit short spans and lighter loads. Heavier gauges (18 and 16) bring added strength and durability, which suits long spans and heavy-duty roofing applications.
Finishes and coatings
| Finish | Details |
|---|---|
| Galvanized G60 | Zinc coating of 0.6 oz/ft². Recommended for general environments. |
| Galvanized G90 | Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments. |
| Prime-Painted | Provides a base coat for additional protection or paint adhesion. |
| Bare Steel | Unfinished; typically for indoor use or controlled environments. |
Several finish options keep the Type N deck performing over the long term, among them galvanized (G60 and G90) and prime-painted. Excellent corrosion resistance comes from galvanizing, and G90 has more zinc for greater exposure to moisture or chemicals. If a project needs additional paint or coating layers, the prime-painted option gives a protective base coat.
Material and finish options
Our Type N 3" Roof Deck uses high-strength 80 KSI steel. It is offered with a corrosion-resistant galvanized finish meeting ANSI standards, prime-painted finishes for added protection, or bare steel for specialized applications. Each finish is engineered for durability and dependable performance in demanding roofing environments.
Custom lengths
Lengths start at 6′-0″ for smaller roofing projects and extend to 40′-0″ for large-scale construction, and the 3" Type N Roof Deck is cut accurately and efficiently. With our custom length service, Hialeah roofers get a better fit, less waste, and simpler installation.
3" Type N Roof Deck features
For large-scale commercial roofing and sustainable buildings, our 3" Type N roof deck provides superior strength, fire-rated performance, and long-span efficiency.
Deep Rib Profile for High Strength
With a 3-inch rib depth, the deck is strong enough for longer spans and heavy roofing loads.
Wide Coverage Efficiency
A standard coverage of 24 inches means less material and easier installation, which is ideal for large-scale projects.
Corrosion-Resistant Finish Options
Choose G60 or G90 galvanized for excellent durability in harsh environmental conditions.
Fire and Acoustic Performance
In approved assemblies it meets fire-rating standards, and it works with insulation for soundproofing and thermal efficiency.
Compliance with SDI Standards
Quality and code compliance are assured by Steel Deck Institute (SDI) and ANSI guidelines.
Long Span Capability
The 22, 20, 18, and 16 gauge options allow customization for specific load-bearing requirements and project demands.
Installation and connections
Installation practices
- Install the deck perpendicular to the supports.
- Weld or screw the deck at each support with puddle welds or TEK screws.
- Overlap sidelaps and secure with screws at 12" o.c. (on center).
Fasteners and attachments
- 5/8" Diameter Puddle Welds
- #12 or #14 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
- Sidelaps attached using #12 TEK screws at 12" o.c.
Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.
Applications

Long-Span Roofing Systems
Where large commercial and industrial roofs need long spans and fewer supports, Type N is the right fit. The 3-inch rib profile provides exceptional strength and efficiency on expansive roof designs.

Fire-Rated Roof Assemblies
Type N is a common choice in fire-rated roof systems because it is compatible with insulation and fireproofing materials. Safety and performance are supported in demanding commercial and industrial applications.
Standards and product documentation
SDI (Steel Deck Institute) specifications are met by the 3" Type N deck, ensuring high standards for design and performance on Hialeah projects.
3" Type N Roof Deck questions
What is 3" Type N Roof Deck used for?
It is designed for long-span roofing, giving structural support to commercial and industrial roof systems.
How far can Type N Roof Deck span?
Depending on gauge, Type N Deck can span up to 16 feet, so fewer intermediate supports are needed.
Which gauges come in 3" Type N Roof Deck?
Gauges run from 16 GA to 22 GA, giving options for different load and span requirements.
Does Type N Roof Deck work with fire-rated roofing systems?
Yes. Type N Deck supports fire-rated assemblies and accommodates insulation and fireproofing materials for added safety.
What finishes does Type N Roof Deck come in?
Galvanized finishes (G60 or G90) resist corrosion, and prime-painted options add protection.
1.5" Type B Vented Roof Deck
The 1.5" Type B Vented Deck is purpose-built for Lightweight Insulated Concrete (LWIC) applications, where it gives better bonding and superior load distribution. Profile depth is 1.5 inches, and gauges range from 22 GA to 18 GA, offering versatility for different jobs in Hialeah. SDI and ANSI standards are met, and galvanized finishes such as G60 and G90 provide durability and corrosion resistance.
Dimensions and profile

| Property | Dimension |
|---|---|
| Profile Depth | 1.5 inches |
| Coverage Width | 36 inches |
| Rib Spacing | 6 inches (center to center) |
| Rib Height | 1.5 inches |
At 1.5 inches deep with a 36 inch standard coverage width, the 1.5" Type B Vented Deck is ideal for Lightweight Insulated Concrete (LWIC) applications. Ribs are spaced 6 inches (center to center), and the overall width of 39 inches allows secure overlaps and strong composite action with concrete slabs. Its perforated profile boosts adhesion and makes sure LWIC cures properly, maximizing strength, durability, and efficiency.
Gauges and thicknesses
| Gauge | Bare steel thickness (in) | Weight (lbs/sq ft) | Typical applications |
|---|---|---|---|
| 22 | 0.0295 | 1.6 | Light-duty roofing and small spans. |
| 20 | 0.0358 | 2 | Medium spans, roofing, and siding. |
| 18 | 0.0474 | 2.6 | Heavy-duty applications. |
| 16 | 0.0598 | 3 | Heavy load spans. |
Gauges 22, 20, and 18 are offered for the Type B Vented Deck, each with its own thickness and load capacity. The lighter 22 and 20 gauges cost less and fit shorter spans. The thicker 18 gauge adds structural strength for longer spans and heavier loads. Perforations strengthen the bond between LWIC and the deck, supporting adhesion and curing in insulated concrete applications.
Finishes and coatings
| Finish | Details |
|---|---|
| Galvanized G60 | Zinc coating of 0.6 oz/ft². Recommended for general environments. |
| Galvanized G90 | Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments. |
| Prime-Painted | Provides a base coat for additional protection or paint adhesion. |
| Bare Steel | Unfinished; typically for indoor use or controlled environments. |
Finish options for the Type B Vented Deck are galvanized (G60 and G90) and prime-painted, selected to protect performance over time. Corrosion resistance comes from the galvanized coatings, with G90 adding protection in highly corrosive environments. A prime-painted deck gets a protective base coat, which is useful when further coatings are planned. The result is a longer deck lifespan and dependable results in LWIC applications.
Material and finish options
The B 1.5" Vented Deck is made from high-strength 50 KSI steel. Options include a corrosion-resistant galvanized finish that meets ANSI/SDI standards, a range of painted finishes for tailored aesthetics, and bare steel for custom applications. Every finish is meant to improve durability and keep performance steady in demanding environments.
Custom lengths
Precise lengths are available from 6′-0″ for smaller projects up to 40′-0″ for larger constructions, and we handle each dimension with efficiency. For Hialeah projects, our custom length service is shaped around your requirements so the fit is optimal and waste is minimal.
1.5" Type B Vented Roof Deck features
Our 1.5" Type B Vented Deck offers lightweight durability, airflow control, and fire resistance, which suits ventilated, efficient commercial applications.
Optimized for LWIC Systems
Created to enhance adhesion in Lightweight Insulated Concrete (LWIC) applications, ensuring proper bonding and structural performance.
Improved Concrete Bonding
The perforations enhance the bond between lightweight concrete and the deck, resulting in a strong roof system and superior load distribution.
Structural & Fire Performance
Complies with SDI and ANSI standards and delivers high durability and fire-rated performance when used in LWIC systems.
LWIC Roofing Applications
Suited to Lightweight Insulated Concrete (LWIC) roof systems, where it provides strength, adhesion, and long-term performance in insulated roofing applications.
Compliance with SDI Standards
Follows Steel Deck Institute (SDI) and ANSI guidelines for quality and code compliance.
Moisture Management
Helps stop moisture from being trapped, which improves durability and lowers the risk of mold or corrosion.
Installation and connections
Installation practices
- Place the deck perpendicular to the supports.
- Secure the deck at each support with puddle welds or TEK screws.
- Overlap sidelaps and fasten them with screws at 12" o.c.
Fasteners and attachments
- 5/8" Diameter Puddle Welds
- #10 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
- Sidelaps attached using #10 TEK screws at 12" o.c.
Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.
Applications

Lightweight Concrete Systems
For composite slabs in LWIC systems, perforations let moisture escape while the concrete cures, which improves bonding. Condensation stays from getting trapped, structural integrity improves, and the insulated concrete system lasts.

Moisture-Controlled Roof Assemblies
In lightweight insulated concrete (LWIC) applications, the perforated profile improves adhesion and curing. Moisture can release as the concrete cures, which protects long-term insulation performance and prevents structural degradation in humid environments.
Standards and product documentation
Hialeah projects specifying the 1.5" B Vented deck get a product that complies with SDI (Steel Deck Institute) specifications, which sets high standards for design and performance.
1.5" Type B Vented Roof Deck questions
Why does the vented Type B deck have perforations?
They improve airflow and moisture control, stop condensation from building up, and improve adhesion in lightweight concrete applications.
How does vented Type B deck help composite systems in Hialeah?
Small perforations strengthen the bond between deck and concrete for stronger composite action. They also let moisture escape, which lowers the chance of water getting trapped.
Can vented Type B deck be used in every roofing application?
Yes, though it helps most in moisture-sensitive settings such as vented roofing systems, where air circulation protects insulation from degradation and corrosion.
Which finishes come on the vented Type B deck?
Galvanized (G60/G90) provides corrosion resistance, and prime-painted finishes provide protection and work with additional coatings.
Do the perforations reduce the structural strength of the vented Type B deck?
No. They are placed strategically so the deck keeps its load capacity and still delivers ventilation benefits for specific applications.
Ordering made simple
Metal Roof Decks for Hialeah construction
Start with your plans or a takeoff. We review the profile, gauge, quantities and lengths, help with shop drawings when you need them, and come back with pricing and a delivery plan for Hialeah.
Send your project requirementsWhat to include in your quote request
- Product profile or series, dimensions, gauge and specified finish.
- Required quantities, sheet or member lengths, and project drawings.
- Project address in Hialeah, delivery date and site access requirements.
- Any specified load tables, connection details or supporting documentation.
How We Work
We Guide You Through the Process
From manufacturing to delivery, we ensure precision, efficiency, and compliance with industry standards.
Takeoff and Shop Drawings Services
We provide specialized takeoff services for accurate quotations and detailed shop drawings to produce optimized cutting lists for sheets, ensuring efficient execution and waste-free outcomes in your projects.
Manufacture
We manufacture metal decks to SDI and ANSI standards, ensuring strength, durability, and compliance. We provide custom lengths and high-precision fabrication for optimized performance in roof, floor, and form deck applications.
Swift Deliveries & Nationwide Reach
While based in South Florida, we serve clients nationwide, ensuring quality, efficiency, and timely deliveries across the U.S., reflecting our commitment to excellence without boundaries.
Frequently Asked Questions
Where can I buy metal roof deck in Hialeah?
Miami Metal Deck supplies metal roof deck to Hialeah with same-day or next-day delivery options. Call 305-760-2575 or request a quote online.
What types of roof deck are available?
We carry Type B (1.5" deep), Type N (3" deep), and Vented Type B roof deck in gauges 16–22 with G60 and G90 galvanized coatings.
Do you offer custom lengths?
Yes. We provide custom-cut lengths from 6 to 40 feet along with shop drawings and takeoff services to support your project.
How many kinds of metal roof deck do you carry?
Three: Type B (1.5" deep), common in general commercial use; Type N (3" deep), for long-span requirements; and Vented Type B Deck, for projects that need moisture control.
In which cases should I specify Type N roof deck over Type B?
Specify Type N roof deck where long spans are involved and fewer supports are preferred, as in warehouses or industrial buildings. Type B remains the usual pick for standard commercial and industrial roofing systems.
What is vented Type B roof deck designed for?
Moisture control. That makes Vented Type B Deck appropriate for Lightweight Insulated Concrete (LWIC) applications.
What coating choices apply to these roof decks?
Galvanized coatings (G60, G90) protect against corrosion on every type, and primer-painted finishes give added protection and a good base for further coating. Ask us about options for Hialeah jobs.