SDI Member · ANSI/SDI compliant

Steel Deck Supplier in Naples

High-performance steel deck in Naples for durable, efficient structures. Roof deck, composite floor deck, and form deck.

Steel Deck Institute Member
SDI Member · ANSI/SDI compliant

Steel Deck for Naples job sites

Builders in Naples order Steel Deck directly from Miami Metal Deck for commercial and industrial projects throughout Collier County and the Southwest Florida region. Deliveries to Naples leave our Miami Gardens facility on a schedule set with your team, with 1-day service available to major Florida cities.

With Naples's coastal humidity and salt air, many engineers specify a G90 galvanized finish for its heavier zinc coating; we confirm the finish against your project specifications. Projects in Naples follow the Florida Building Code wind-load requirements, so we work directly from your engineer's deck schedule, gauges and attachment details.

Product guide

Product specifications for your Naples project

Compare profiles, dimensions, material options and applications to prepare your order. Select a product below to explore its technical details.

1.5" Type B Roof Deck

A dependable roofing choice, the 1.5 Type B metal deck is supplied from Miami, Florida and installs without fuss. Structural strength is excellent, gauges run from 22 GA to 16 GA, and the deck meets SDI and ANSI standards. Galvanized finishes such as G60 and G90 add corrosion resistance and durability, which helps contractors in Naples match the deck to the job.

Dimensions and profile

1.5" Type B Roof Deck profile dimensions
1.5" Type B Roof Deck dimensions
PropertyDimension
Profile Depth1.5 inches
Coverage Width36 inches
Rib Spacing6 inches (center to center)
Rib Height1.5 inches

With a 1.5 inch rib depth and a 36 inch standard coverage width, the 1.5" Type B metal deck is structurally efficient for roofing and flooring. The 6 inch rib spacing (center to center) and 39 inch overall material width allow secure overlaps and strong composite action when concrete slabs are added. Strength is maximized and weight is minimized, which keeps the deck durable and versatile on all sorts of construction jobs.

Gauges and thicknesses

1.5" Type B Roof Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.6Light-duty roofing and small spans.
200.03582Medium spans, roofing, and siding.
180.04742.6Heavy-duty applications.
160.05983Heavy load spans.

There are four gauges to choose from for Type B deck: 22, 20, 18, and 16. Each has different thickness and load capacity, so you can fit the deck to the project. Light and cost-effective, 22 and 20 gauge are best on shorter spans and lighter loads. Stronger 18 and 16 gauge carry longer spans and heavier loads, which makes them ideal for demanding applications.

Finishes and coatings

1.5" Type B Roof Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

For lasting performance, Type B deck is offered with galvanized (G60 and G90) and prime-painted finishes, among others. Galvanizing gives excellent corrosion resistance, and G90 has the higher zinc coating for environments with more exposure to moisture or chemicals. If the project needs extra paint or coating layers, the prime-painted option supplies a protective base coat.

Material and finish options

Steel is offered in 33 KSI, 40 KSI, 50 KSI, and 80 KSI grades, each engineered for a particular structural demand and balancing strength against flexibility. Both galvanized (G60/G90) and prime-painted finishes conform to ASTM A653 for corrosion resistance.

Custom lengths

Deck lengths start at 6′-0″ for compact jobs and run up to 40′-0″ for large structures, so we can fit nearly any layout in Naples. Cutting to your custom length keeps waste low and the deck fitting properly on site.

1.5" Type B Roof Deck features

Lightweight yet durable, our 1.5" Type B metal deck also brings fire resistance and a sustainable design. It is a practical, eco-friendly pick for short-span commercial projects.

High Strength-to-Weight Ratio

Handles substantial load for its weight, a strong fit for roofing systems.

Standard 36 inches Coverage

Each sheet covers 36 inches with a uniform rib design, so crews finish faster and work more efficiently.

Galvanized or Prime-Painted Finish

G60/G90 galvanized and prime-painted finishes are both available to improve durability and corrosion resistance.

Compatibility with Roofing Systems

Supports insulation, waterproofing, reflective coatings, drainage, ventilation, and other roofing components.

Compliance with Standards

Quality and code compliance are backed by Steel Deck Institute (SDI) and ANSI guidelines.

Wide Gauge Range

The 22, 20, 18, and 16 gauge options let you match the deck to the load-bearing needs and demands of the project.

Installation and connections

Installation practices

  • Place the deck perpendicular to the supports.
  • Secure the deck to each support using puddle welds or TEK screws.
  • Overlap the sidelaps, then screw them down at 12" o.c.

Fasteners and attachments

  • 5/8" Diameter Puddle Welds
  • #10 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
  • Sidelaps attached using #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Roof Deck Applications

Roof Deck Applications

Commercial and industrial roof systems that demand structural strength and durability rely heavily on Type B. It carries roofing insulation systems and works for vented as well as non-vented roofs.

Hybrid Structural-Ceiling Systems

Hybrid Structural-Ceiling Systems

Type B can also serve as an exposed ceiling in architectural spaces. It gives structural strength and a clean look while trimming extra materials and installation time.

Standards and product documentation

For Naples contractors, the 1.5" Type B deck complies with SDI (Steel Deck Institute) specifications, supporting high standards of design and performance.

1.5" Type B Roof Deck questions

Which gauge is typical for Type B decking?

20 gauge is generally the most common, as it balances cost and strength for typical applications. Other gauges may be needed depending on project-specific requirements.

G60 versus G90 galvanized: what is the difference?

G60 carries 0.60 oz/ft² of coating, and G90 carries 0.90 oz/ft². The extra 50% zinc in G90 gives greater corrosion resistance. Use G60 indoors or in low-moisture environments. Use G90 outdoors, on roofing and steel decking, and on structures exposed to weather, humidity, or corrosive conditions.

What maximum spans can the 1.5" Type B deck achieve?

Maximum spans vary with gauge, span type, and load requirements. 22-gauge decks, for example, can span up to 8 feet under multiple spans, while 16-gauge decks can span up to 14 feet. Always consult load tables for precise details.

Is customization available for 1.5" Type B metal decking on Naples jobs?

Yes. Gauge, finish, and length can be customized. Cutting lengths to project needs reduces waste and optimizes installation efficiency.

Does 1.5" Type B metal decking satisfy industry standards?

Yes. Steel Deck Institute (SDI) standards and American Iron and Steel Institute (AISI) design guidelines are both met, which ensures quality, safety, and compatibility with construction codes.

3" Type N Roof Deck

Because of its long-span capability and structural strength, 3" Type N metal deck is widely specified for roofs. The Type N profile is 3 inches deep, with gauges from 22 GA to 16 GA for flexibility on roofing projects in Naples. It complies with SDI and ANSI standards and is offered in galvanized finishes such as G60 and G90.

Dimensions and profile

3" Type N Roof Deck profile dimensions
3" Type N Roof Deck dimensions
PropertyDimension
Profile Depth3 inches
Coverage Width24 inches
Rib Spacing8 inches (center to center)
Rib Height3 inches

Depth of profile is 3 inches and coverage width is 24 inches on the Type N Roof Deck. Rib spacing measures 8 inches (center to center), and rib height is 3 inches. A deep rib like this gives the strength needed for longer spans and heavy roofing loads, and the wide coverage makes large roofs quicker to cover.

Gauges and thicknesses

3" Type N Roof Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.8Light duty roofs.
200.03582.2Standard commercial roofs.
180.04742.9Heavy load areas.
160.05983.7Long spans, high loads.

Choose from 22, 20, 18, and 16 gauge when ordering Type N Roof Deck. Thickness and load capacity differ by gauge, so you can fit the deck to the roofing project. For shorter spans and lighter loads, lighter gauges (22 and 20) are economical. For long spans and heavy-duty roofing, heavier gauges (18 and 16) deliver extra strength and durability.

Finishes and coatings

3" Type N Roof Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Type N deck is available with several finishes for lasting performance, including galvanized (G60 and G90) and prime-painted. Galvanizing resists corrosion well, and G90 has a heavier zinc coating for environments with more moisture or chemical exposure. Prime paint adds a base coat, so it fits projects that call for extra paint or coatings.

Material and finish options

The Type N 3" Roof Deck is made from high-strength 80 KSI steel. Choose a corrosion-resistant galvanized finish that meets ANSI standards, prime-painted finishes for extra protection, or bare steel for specialized applications. Each finish is engineered for durability and dependable performance in demanding roofing environments.

Custom lengths

Lengths start at 6′-0″ for smaller roofing projects and extend to 40′-0″ for large-scale construction, and the 3" Type N Roof Deck is cut accurately and efficiently. With our custom length service, Naples roofers get a better fit, less waste, and simpler installation.

3" Type N Roof Deck features

For large-scale commercial roofing and sustainable buildings, our 3" Type N roof deck provides superior strength, fire-rated performance, and long-span efficiency.

Deep Rib Profile for High Strength

The 3-inch rib depth gives superior strength, which suits longer spans and heavy roofing loads.

Wide Coverage Efficiency

Standard 24-inch coverage lowers material usage and simplifies installation, perfect for large-scale projects.

Corrosion-Resistant Finish Options

G60 or G90 galvanized finishes are available, with excellent durability and resistance to harsh environmental conditions.

Fire and Acoustic Performance

Fire-rating standards are met when used in approved assemblies, and insulation is supported for soundproofing and thermal efficiency.

Compliance with SDI Standards

Follows Steel Deck Institute (SDI) and ANSI guidelines, so quality and code compliance are ensured.

Long Span Capability

Offered in 22, 20, 18, and 16 gauges to customize for load-bearing requirements and project demands.

Installation and connections

Installation practices

  • Set the deck perpendicular to the supports.
  • Secure the deck to each support using puddle welds or TEK screws.
  • Overlap the sidelaps and screw them down at 12" o.c. (on center).

Fasteners and attachments

  • 5/8" Diameter Puddle Welds
  • #12 or #14 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
  • Sidelaps attached using #12 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Long-Span Roofing Systems

Long-Span Roofing Systems

Large commercial and industrial roofs that need long spans and fewer supports are a perfect match for Type N. The 3-inch rib profile gives exceptional strength and efficiency across expansive roof designs.

Fire-Rated Roof Assemblies

Fire-Rated Roof Assemblies

Fire-rated roof systems commonly use Type N, which works with insulation and fireproofing materials. It supports safety and performance in demanding commercial and industrial applications.

Standards and product documentation

The 3" Type N deck complies with SDI (Steel Deck Institute) specifications, which sets high standards for design and performance on Naples roofs.

3" Type N Roof Deck questions

What is the 3" Type N Roof Deck for?

Long-span roofing applications. It supplies structural support for commercial and industrial roof systems.

What span capability does Type N Roof Deck offer?

Up to 16 feet, depending on gauge, which cuts down on intermediate supports.

What gauges does the 3" Type N Roof Deck come in?

Gauges from 16 GA to 22 GA are available, giving options for different load and span requirements.

Can Type N Roof Deck be used in fire-rated roofing systems?

Yes. Type N Deck supports fire-rated assemblies and fits insulation and fireproofing materials for enhanced safety on Naples buildings.

What finishes are offered on Type N Roof Deck?

Galvanized finishes (G60 or G90) provide corrosion resistance, and prime-painted options give additional protection.

1.5" Type B Vented Roof Deck

Designed for Lightweight Insulated Concrete (LWIC) applications, the 1.5" Type B Vented Deck improves bonding and load distribution. This vented Type B profile is 1.5 inches deep and comes in gauges from 22 GA to 18 GA, so it adapts to different projects in Naples. It complies with SDI and ANSI standards and is offered in galvanized finishes such as G60 and G90 for durability and corrosion resistance.

Dimensions and profile

1.5" Type B Vented Roof Deck profile dimensions
1.5" Type B Vented Roof Deck dimensions
PropertyDimension
Profile Depth1.5 inches
Coverage Width36 inches
Rib Spacing6 inches (center to center)
Rib Height1.5 inches

At 1.5 inches deep with a 36 inch standard coverage width, the 1.5" Type B Vented Deck is ideal for Lightweight Insulated Concrete (LWIC) applications. Ribs are spaced 6 inches (center to center), and the overall width of 39 inches allows secure overlaps and strong composite action with concrete slabs. Its perforated profile boosts adhesion and makes sure LWIC cures properly, maximizing strength, durability, and efficiency.

Gauges and thicknesses

1.5" Type B Vented Roof Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.6Light-duty roofing and small spans.
200.03582Medium spans, roofing, and siding.
180.04742.6Heavy-duty applications.
160.05983Heavy load spans.

Type B Vented Deck can be ordered in gauges 22, 20, and 18, which differ in thickness and load capacity to fit the needs of each project. Lighter gauges (22 and 20) are cost-effective and best for shorter spans. The thicker 18 gauge brings greater structural strength to support longer spans and heavier loads. In insulated concrete applications, the perforated design strengthens the bond with LWIC for proper adhesion and curing.

Finishes and coatings

1.5" Type B Vented Roof Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Both galvanized (G60 and G90) and prime-painted finishes are offered on the Type B Vented Deck for durability and long-term performance. G90 gives galvanized coatings extra protection in highly corrosive environments, and all galvanized options resist corrosion. For projects that need additional coatings, prime paint supplies a protective base coat. These finishes lengthen deck life and maintain performance in LWIC applications.

Material and finish options

The B 1.5" Vented Deck is made from high-strength 50 KSI steel. Options include a corrosion-resistant galvanized finish that meets ANSI/SDI standards, a range of painted finishes for tailored aesthetics, and bare steel for custom applications. Every finish is meant to improve durability and keep performance steady in demanding environments.

Custom lengths

Precise lengths are available from 6′-0″ for smaller projects up to 40′-0″ for larger constructions, and we handle each dimension with efficiency. For Naples projects, our custom length service is shaped around your requirements so the fit is optimal and waste is minimal.

1.5" Type B Vented Roof Deck features

Our 1.5" Type B Vented Deck offers lightweight durability, airflow control, and fire resistance, which suits ventilated, efficient commercial applications.

Optimized for LWIC Systems

Built to improve adhesion in Lightweight Insulated Concrete (LWIC) applications for proper bonding and structural performance.

Improved Concrete Bonding

Perforations strengthen the bond between the deck and lightweight concrete, giving a robust roof system with better load distribution.

Structural & Fire Performance

SDI and ANSI compliant, with high durability and fire-rated performance in LWIC systems.

LWIC Roofing Applications

A strong fit for Lightweight Insulated Concrete (LWIC) roof systems, with strength, adhesion, and long-term performance in insulated roofing.

Compliance with SDI Standards

Steel Deck Institute (SDI) and ANSI guidelines are met, which assures quality and code compliance.

Moisture Management

Helps prevent trapped moisture, which improves durability and lowers the risk of mold or corrosion.

Installation and connections

Installation practices

  • Run the deck perpendicular to the supports.
  • Attach the deck at every support by puddle weld or TEK screw.
  • Overlap the sidelaps and fasten with screws at 12" o.c.

Fasteners and attachments

  • 5/8" Diameter Puddle Welds
  • #10 TEK screws at 6" o.c. on edges, and 12" o.c. for sidelaps
  • Sidelaps attached using #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Lightweight Concrete Systems

Lightweight Concrete Systems

Composite slabs in LWIC systems benefit from the perforations, which let moisture escape during curing and so improve concrete bonding. Trapped condensation is avoided, structural integrity improves, and the insulated concrete system stays durable.

Moisture-Controlled Roof Assemblies

Moisture-Controlled Roof Assemblies

Designed with lightweight insulated concrete (LWIC) in mind, the perforated profile improves adhesion and curing. Releasing moisture as the concrete cures supports insulation performance over the long term and guards against structural degradation in humid environments.

Standards and product documentation

SDI (Steel Deck Institute) specifications are met by the 1.5" B Vented deck, ensuring high standards for design and performance on Naples jobs.

1.5" Type B Vented Roof Deck questions

What do the perforations do on vented Type B deck?

Airflow and moisture control improve, condensation is kept from building up, and adhesion gets better in lightweight concrete applications.

In what way does vented Type B deck improve composite systems?

The bond between deck and concrete is enhanced by the small perforations, giving stronger composite action. Moisture can also escape, so there is less risk of trapped water.

Does vented Type B deck work for all Naples roofing applications?

Yes. It offers the most benefit in moisture-sensitive environments like vented roofing systems, where air circulation helps keep insulation from degrading and corroding.

What finishes can I order on vented Type B deck?

Choose galvanized (G60/G90) for corrosion resistance or prime-painted finishes for protection and compatibility with additional coatings.

Is structural strength affected by the vented Type B deck perforations?

No. Perforations are placed strategically, so load capacity is maintained while ventilation benefits apply to specific applications.

1.5" Composite Floor Deck

The 1.5" composite floor deck gives Naples projects a high strength-to-weight ratio and bonds directly to poured concrete, which improves the structural efficiency of the slab. It is offered in 22 GA to 16 GA with G60 or G90 galvanized finishes, and it meets SDI and ANSI standards.

Dimensions and profile

1.5" Composite Floor Deck profile dimensions
1.5" Composite Floor Deck dimensions
PropertyDimension
Profile Depth1.5 inches
Coverage Width36 inches
Rib Spacing6 inches (center to center)
Material Width39 inches

This deck has a 1.5 inch rib depth and a 36 inch coverage width. Ribs are spaced 6 inches center to center, and the 39 inch material width gives the overlaps needed for secure laps and strong composite action with the concrete slab.

Gauges and thicknesses

1.5" Composite Floor Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.6Light-duty spans.
200.03582Medium spans.
180.04742.6Heavy-duty applications.
160.05983Heavy load spans.

Four gauges are stocked for the 1.5" composite floor deck: 22, 20, 18, and 16. The lighter 22 and 20 gauges are economical and easy to handle, while 18 and 16 gauge provide more structural strength where loads are heavier.

Finishes and coatings

1.5" Composite Floor Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

The 1.5" composite floor deck ships in G60 or G90 galvanized and in prime-painted. Galvanized coatings resist corrosion best, and prime paint gives projects a protective base for added coatings. Both G60 and G90 meet ASTM A653.

Material and finish options

Our 1.5" composite floor deck uses high-strength steel and is offered galvanized to SDI/ANSI standards, painted for enhanced aesthetics, or bare for specialized applications. Each choice is made for durability and dependable results.

Custom lengths

Need 6′-0″ pieces for a small project or 40′-0″ spans for a big one? We cut deck to your lengths, so it fits correctly and you throw away less. Cut lengths are available for Naples jobs of any size.

1.5" Composite Floor Deck features

Our 1.5" composite floor deck is built for commercial and residential floor systems, with dependable concrete bonding, compatibility with fire-rated assemblies, and SDI-compliant performance.

High Strength-to-Weight Ratio

Delivers exceptional load capacity at minimal weight, ideal for composite floor systems.

Structural Efficiency

Forms a composite system with concrete, with superior strength from the concrete bond.

Galvanized or Prime-Painted Finish

Durable, corrosion-resistant G60/G90 galvanized or prime-painted finishes.

Fireproofing Compatible

Accepts fireproofing materials and fire ratings for added safety in commercial and residential work.

Complies with SDI

Meets Steel Deck Institute (SDI) and ANSI guidelines for code compliance and quality.

Optimized for Spans

Gauges 22, 20, 18, and 16 keep deflection low in composite floor applications.

Installation and connections

Installation practices

  • Place the deck perpendicular to the supports.
  • Fasten edges with 5/8" diameter puddle welds or #10 TEK screws at 6".
  • Fasten sidelaps with #10 TEK screws at 12" o.c.

Fasteners and attachments

  • Puddle welds, 5/8" diameter
  • Edge fastening with #10 TEK screws at 6" o.c.
  • Sidelap fastening with #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Composite Floor Systems

Composite Floor Systems

Acts as permanent formwork and bonds to the concrete slab, which lowers deflection and raises strength.

Mezzanine Flooring

Mezzanine Flooring

A durable base for mezzanine floors in warehouses and commercial buildings that carries heavy loads and goes in quickly.

Standards and product documentation

For Naples projects, the 1.5" composite floor deck complies with SDI (Steel Deck Institute) specifications and ANSI standards, ensuring high standards for design and performance.

1.5" Composite Floor Deck questions

What is the 1.5" composite floor deck designed to do?

It carries concrete slabs as permanent formwork and creates a composite system with greater strength and load-bearing capacity.

Which gauges does it come in when building in Naples?

22 GA to 16 GA. Heavier gauges handle bigger loads and longer spans.

Which finishes can I get?

Galvanized in G60 or G90, which offers superior corrosion resistance, as well as prime-painted and bare steel.

Can the deck be ordered in custom lengths?

Yes. It can be cut anywhere from 6'-0" to 40'-0" to keep waste to a minimum.

Why is the 1.5" composite deck a good floor choice?

Embossed ribs create a mechanical bond with concrete, so the slab and steel deck share load as a structural composite.

2" Composite Floor Deck

For floor systems that call for composite bonding with concrete, the 2" composite floor deck is a flexible choice. Its 2 inch depth and 22 GA to 16 GA gauges let it take on heavier loads and longer spans, including on projects around Naples.

Dimensions and profile

2" Composite Floor Deck profile dimensions
2" Composite Floor Deck dimensions
PropertyDimension
Profile Depth2 inches
Coverage Width36 inches
Rib Spacing12 inches (center to center)
Rib Height2 inches

Rib depth measures 2 inches and the standard coverage width is 36 inches. A 12 inch rib spacing (center to center) and the overall material width let sheets overlap securely and bond well with concrete. This profile is engineered for top load capacity and long spans.

Gauges and thicknesses

2" Composite Floor Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.6Light-duty roofing and small spans.
200.03582Medium spans, roofing, and siding.
180.04742.6Heavy-duty applications.
160.05983Heavy load spans.

The 2" composite floor deck comes in gauges 22 through 16 for varied load and span demands. Choose 22 or 20 gauge for lightweight, economical deck on shorter spans and lighter loads. Choose 18 or 16 gauge for higher strength on longer spans and heavier loads.

Finishes and coatings

2" Composite Floor Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Several finishes are offered on the 2" composite floor deck, including galvanized (G60 and G90) and prime-painted, for long service life. Galvanizing gives superior corrosion resistance. Prime paint is a protective base coat, useful when paint or other coatings will follow.

Material and finish options

The 2" composite floor deck is made from high-performance 50 KSI steel. Pick galvanized finishes that meet SDI/ANSI standards, painted finishes for a better look, or bare steel for specialized applications, and expect durable performance in varied construction settings.

Custom lengths

Whether you need 6′-0″ lengths for a small project or runs up to 40′-0″ for a large one, we can cut deck to your specification. The result is a precise fit with minimal waste. Cut lengths are available for Naples jobs of any size.

2" Composite Floor Deck features

The 2" composite floor deck delivers high load-bearing capacity, structural efficiency, and reliable concrete bonding. It is an efficient, sustainable option for heavy-duty floor construction.

Heavy Load Capacity

Built to carry heavier loads, suited to industrial floors and demanding uses.

Efficient Composite System

Combines with concrete to give superior strength and allow a thinner floor.

Galvanized or Prime-Painted Finish

G60/G90 galvanized or prime-painted finishes resist corrosion and wear.

Less Concrete Needed

Uses less concrete, cutting material cost while keeping strength.

SDI and ANSI Compliant

Meets Steel Deck Institute (SDI) and ANSI guidelines for quality and code compliance.

Made for Long Spans

Spans longer distances with minimal deflection.

Installation and connections

Installation practices

  • Set the deck perpendicular to the supports.
  • At each support, attach the deck with puddle welds or TEK screws.
  • Overlap the sidelaps and fasten them with screws at 12" o.c.

Fasteners and attachments

  • Puddle welds, 5/8" diameter
  • Edges fastened with #10 TEK screws spaced 6" o.c.
  • Sidelaps fastened with #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Composite Floor Systems

Composite Floor Systems

Bonds to concrete slabs, reducing deflection and increasing strength for heavy-duty floors in multi-story commercial and residential buildings.

Mezzanine Flooring

Mezzanine Flooring

A durable base for warehouse and industrial mezzanines that supports heavy loads and installs efficiently.

Standards and product documentation

For Naples projects, the 2" composite floor deck complies with SDI (Steel Deck Institute) specifications, ensuring high standards for design and performance.

2" Composite Floor Deck questions

What is the main use for the 2" composite floor deck?

It works as permanent formwork for concrete slabs and forms a composite system, which boosts structural strength and load-bearing capacity.

What gauge range is available for jobs in Naples?

Gauges run 22 GA to 16 GA, and the thicker gauges are better for heavier loads and longer spans.

What finishes are available?

Galvanized (G60 or G90) with superior corrosion resistance, prime-painted, and bare steel.

Does it come in custom lengths?

Yes. Deck can be cut from 6'-0" to 40'-0" with minimal waste.

Why is it suited to demanding applications?

The 2 inch depth is deeper than shallower decks, so it supports greater spans and heavier loads.

3" Composite Floor Deck

The 3" composite floor deck suits floor systems that must span farther and carry more load. At 3 inches deep and in 22 GA to 16 GA, it offers superior strength and durability to builders in Naples. SDI and ANSI standards apply, and G60 and G90 galvanized finishes help it resist corrosion.

Dimensions and profile

3" Composite Floor Deck profile dimensions
3" Composite Floor Deck dimensions
PropertyDimension
Profile Depth3 inches
Coverage Width36 inches
Rib Spacing12 inches (center to center)
Rib Height3 inches

This profile has a 3 inch rib depth and 36 inch standard coverage width for superior strength in heavy-duty composite floor systems. Rib spacing is 12 inches (center to center), with a 36 inch overall material width, which provides efficient overlaps and excellent concrete bonding. It is engineered for maximum load capacity and extended spans in demanding construction.

Gauges and thicknesses

3" Composite Floor Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02951.6Light-duty roofing and small spans.
200.03582Medium spans, roofing, and siding.
180.04742.6Heavy-duty applications.
160.05983Heavy load spans.

Gauges for the 3" composite floor deck range from 22 to 16, which covers many load and span requirements. Thinner gauges (22 and 20) are light and economical for shorter spans and lighter loads. Thicker gauges (18 and 16) provide more structural strength for longer spans and heavier loads, and add reliability in tougher applications.

Finishes and coatings

3" Composite Floor Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Multiple finishes are offered on the 3" composite floor deck, including galvanized (G60 and G90) and prime-painted, to ensure durability and long-term performance. Galvanizing provides superior corrosion resistance, and G90 has a higher zinc coating for greater exposure to moisture or chemicals. Prime paint acts as a protective base coat, ideal if you plan to paint or add coatings.

Material and finish options

Made from high-performance 50 KSI steel, the 3" composite floor deck can be galvanized to SDI/ANSI standards, painted for enhanced aesthetics, or left bare for specialized applications. In all cases it is built for durable, reliable performance in diverse construction settings.

Custom lengths

Deck can be furnished at lengths from 6′-0″ for smaller jobs to 40′-0″ for larger ones. We cut to your exact requirements so the fit is right and waste stays low. This applies to every Naples order.

3" Composite Floor Deck features

Our 3" composite floor deck combines remarkable strength, extended spans, and reliable concrete bonding for heavy-duty, efficient, and sustainable floor systems.

Superior Strength Under Load

Engineered for heavy loads, ideal for industrial applications and demanding construction environments.

Efficient Composite Behavior

Works with concrete to form a composite system that maximizes strength while reducing floor thickness.

Galvanized or Prime-Painted Finish

Select G60/G90 galvanized or prime-painted finishes for improved durability and corrosion resistance.

Fireproofing Compatible

Accommodates fireproofing materials and fire ratings, for added safety on commercial and residential projects.

SDI Standards Compliance

Conforms to Steel Deck Institute (SDI) and ANSI guidelines, assuring quality and code compliance.

Extended Span Capability

Its 3 inch profile supports longer spans and lessens the need for added structural supports in large projects.

Installation and connections

Installation practices

  • Install the deck perpendicular to the supports.
  • At each support, weld or screw the deck down with puddle welds or TEK screws.
  • Overlap sidelaps and fasten them with screws at 12" o.c.

Fasteners and attachments

  • Puddle welds, 5/8" diameter
  • #10 TEK screws at 6" o.c. on edges, 12" o.c. on sidelaps
  • Sidelap fastening with #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Long-Span Composite Floors

Long-Span Composite Floors

Suited to long spans that reduce the need for columns, the 3" Composite Floor Deck boosts structural efficiency and supports heavy loads in warehouses, distribution centers, and big commercial spaces.

Heavy Equipment Platforms

Heavy Equipment Platforms

In industrial facilities and manufacturing plants, the 3" Composite Floor Deck builds durable platforms for heavy machinery that handle concentrated loads and distribute them better.

Standards and product documentation

Specifiers in Naples can count on the 3" composite floor deck to follow SDI (Steel Deck Institute) specifications, which sets high design and performance standards.

3" Composite Floor Deck questions

What is the primary purpose of the 3" composite floor deck?

The 3" Composite Floor Deck is permanent formwork that structurally supports concrete slabs and forms a composite system well suited to long spans and heavy loads.

What gauges are available for the 3" composite floor deck for jobs in Naples?

22 GA to 16 GA, which gives flexibility across load capacities and structural requirements.

What finishes can I order for the 3" composite floor deck?

Galvanized (G60 or G90) finishes resist corrosion, prime-painted suits projects needing more coatings, and bare steel is for specific applications.

Is custom length cutting offered for the 3" composite floor deck?

Yes, from 6'-0" to 40'-0", for a precise fit and less material waste on site.

What makes the 3" composite floor deck right for large-scale projects?

The deeper 3 inch profile carries longer spans and heavier loads, which is why it is preferred in industrial facilities, warehouses, and multi-story construction requiring maximum durability.

9/16" Type S Form Deck

Permanent formwork for concrete slabs in floor and roof systems is the main job of Type S Form Deck, valued for its strength and easy installation. Contractors in Naples can order it in gauges from 28 GA to 20 GA, manufactured to SDI and ANSI standards.

Dimensions and profile

9/16" Type S Form Deck profile dimensions
9/16" Type S Form Deck dimensions
PropertyDimension
Profile Depth9/16 inches
Coverage Width36 inches
Rib Spacing2.57 inches (center to center)
Rib Height9/16 inches

With a shallow rib depth of 9/16 inch and a standard 36-inch coverage width, Type S Form Deck is well suited to quick concrete slab forming. Ribs sit 2.57 inches apart (center to center), giving a steady forming surface that limits concrete volume while keeping the structure sound.

Gauges and thicknesses

9/16" Type S Form Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
280.01490.65Light-duty concrete formwork, low-load applications.
260.01790.75Standard concrete slabs.
240.02391.0Medium-duty floor and roof slabs.
220.02991.25Medium-duty floors, multi-level buildings.
200.03581.5Heavy-duty formwork, bridges.

Type S Form Deck comes in gauges 28, 26, 24, 22, and 20. Gauges 28 and 26, the lighter ones, are economical for standard concrete slabs. Gauges 22 and 20 deliver greater strength for longer spans and heavier concrete loads, as in bridges and industrial floors.

Finishes and coatings

9/16" Type S Form Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Finish choices for Type S Form Deck are galvanized (G60 and G90) and prime-painted. The galvanized coatings resist corrosion, and G90 adds protection where conditions are highly corrosive. Both G60 and G90 conform to ASTM A653.

Material and finish options

Type S Form Deck uses high-strength 80 KSI steel and ships with a corrosion-resistant galvanized finish that meets SDI/ANSI standards. Painted finishes are offered for tailored aesthetics, and bare steel is available for custom applications. Each option is intended to extend durability and sustain performance in demanding environments.

Custom lengths

From 6′-0″ pieces for smaller projects to spans reaching 40′-0″ for larger construction, we supply the dimensions you need. Our custom length service is set up around your requirements, so the deck fits well and little material is wasted.

9/16" Type S Form Deck features

Type S Form Deck delivers high structural strength, efficient concrete forming, and corrosion-resistant finishes at a sensible price. It adapts well to multi-level buildings, bridges, and tunnels.

High Structural Strength

Designed to support concrete slabs, giving stability and structural strength during and after concrete placement.

Efficient Concrete Formwork

This quick-to-build form deck suits slab forming in multi-level buildings, bridges, and tunnels, and it reduces labor time and material costs.

Galvanized or Prime-Painted Finish

G60/G90 galvanized or prime-painted finishes add durability and corrosion resistance where conditions are demanding.

Cost-Effective Solution

A lightweight, shallow profile limits concrete use while offering a stable forming surface, so overall project costs drop.

Compliance with SDI Standards

Conforms to Steel Deck Institute (SDI) and ANSI guidelines, supporting quality and code compliance.

Versatile Design Options

Gauges 28 through 20, G60/G90 galvanized coatings, and custom lengths between 6 and 40 feet.

Installation and connections

Installation practices

  • Place the deck at right angles to the supports.
  • Attach it at every support with pins, powder-actuated fasteners, or TEK screws.
  • Overlap the sidelaps and fasten them with screws at 12" o.c.

Fasteners and attachments

  • Deck is secured to supports with pins or powder-actuated fasteners
  • #10 TEK screws at 6" o.c. on edges and 12" o.c. for sidelaps
  • Sidelaps are attached by button punching or by #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Composite Floor Slabs

Composite Floor Slabs

A good match for forming slabs in multi-level buildings, bridges, and tunnels. The shallow rib profile uses less concrete and gives an efficient, stable forming surface.

Bridge and Tunnel Formwork

Bridge and Tunnel Formwork

Bridge decks and tunnel construction often use Type S Form Deck as permanent concrete formwork, since it supports the structure while concrete is being placed.

Standards and product documentation

Type S Form Deck is built to SDI (Steel Deck Institute) specifications and ANSI standards, which supports consistent design and performance for Naples projects.

9/16" Type S Form Deck questions

Why use Type S form deck?

Type S form deck acts as permanent formwork for concrete slabs in floor and roof systems. It gives a stable base while concrete is placed and stays put after curing.

Is form deck the same as composite deck?

No. Form deck serves only as formwork, so the cured concrete slab carries the load independently. Composite deck bonds structurally with the concrete and shares load permanently.

What are the Type S form deck gauge options?

28, 26, 24, 22, and 20 GA, with thickness from 0.0149" to 0.0358".

Which fastening methods work for Type S form deck?

Pins, powder-actuated fasteners, or TEK screws attach the deck. Button punching or #10 TEK screws at 12" o.c. secure the sidelaps.

Does Type S form deck come in custom lengths?

Yes, in lengths from 6'-0" to 40'-0". That reduces waste and fits each project precisely, including work in Naples.

1" Type HD Form Deck

Heavy-duty concrete formwork in floors and roofs is the purpose of Type HD Form Deck, which delivers strong support and durability. Gauges run from 26 GA to 20 GA, so it copes with greater loads and longer spans. SDI and ANSI standards apply, and galvanized finishes such as G60 and G90 improve corrosion resistance for Naples projects.

Dimensions and profile

1" Type HD Form Deck profile dimensions
1" Type HD Form Deck dimensions
PropertyDimension
Profile Depth1 inch
Coverage Width36 inches
Rib Spacing4 inches (center to center)
Rib Height1 inch

Type HD Form Deck has a 1-inch rib depth and a standard 36-inch coverage width, a fit for heavy-duty concrete formwork in floors and roofs. Ribs are spaced 4 inches (center to center), and the overall material width of 39 inches gives secure overlaps and solid concrete support. The profile carries greater loads and holds down material costs, which helps on demanding construction projects.

Gauges and thicknesses

1" Type HD Form Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
260.01790.75Light-duty concrete formwork, low-load floors.
240.02391.0Standard floors, light industrial applications.
220.02991.25Medium-duty floors, parking structures.
200.03591.5Heavy-duty formwork, bridges, industrial slabs.

Type HD Form Deck is made in gauges 26, 24, 22, and 20. Standard concrete slabs and moderate spans are handled economically by the lighter gauges (26 and 24). The heavier gauges (22 and 20) offer superior strength over longer spans and under heavier concrete loads, ideal for industrial floors, bridges, and parking structures.

Finishes and coatings

1" Type HD Form Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

For durability and long-term performance, Type HD Form Deck is supplied in galvanized (G60 and G90) and prime-painted finishes. Galvanizing gives excellent corrosion resistance, and G90 has a thicker zinc layer to protect in high-moisture or chemical environments. The prime-painted finish adds a protective base coat. G60 and G90 finishes conform to ASTM A653 specifications.

Material and finish options

Type HD Deck is high-strength 80 KSI steel. Order it with a corrosion-resistant galvanized finish that meets SDI/ANSI standards, with a choice of painted finishes for tailored aesthetics, or as bare steel for custom applications. Each finish is intended to extend durability and sustain performance in demanding environments.

Custom lengths

Pick deck lengths from 6′-0″ for smaller projects to 40′-0″ for large spans. We work to your specified dimensions, with the aim of an optimal fit and minimal waste.

1" Type HD Form Deck features

Heavy-duty load support, efficient concrete bonding, and enhanced durability define our 1" Type HD Form Deck, a strong pick for industrial floors, bridge formwork, and demanding structural applications in Naples.

Heavy-Duty Load Support

Type HD Form Deck is engineered for higher concrete loads, which makes it right for projects needing superior strength and stability.

Efficient Concrete Bonding

Its deep profile accommodates thicker concrete slabs, giving better load distribution and lasting performance.

Galvanized or Prime-Painted Finish

Select G60/G90 galvanized or prime-painted finishes for added durability and corrosion resistance.

Cost-Effective Formwork Solution

Parking structures, bridge formwork, and industrial floors are typical heavy-duty uses, and the deck adapts easily to complex construction needs.

Compliance with SDI Standards

Steel Deck Institute (SDI) and ANSI guidelines are met, ensuring quality and code compliance.

Versatile Gauge Options

From 26 GA to 20 GA, there is flexibility to meet specific load requirements and stay durable.

Installation and connections

Installation practices

  • Run the deck perpendicular to the supports.
  • At each support, secure the deck with pins, powder-actuated fasteners, or TEK screws.
  • Overlap the sidelaps and fasten with screws at 12" o.c.

Fasteners and attachments

  • Pins or powder-actuated fasteners secure the deck to supports
  • #10 TEK screws at 6" o.c. on edges and 12" o.c. for sidelaps
  • Sidelaps fastened using button punching or #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Heavy Industrial Floor Systems

Heavy Industrial Floor Systems

High-load equipment and machinery on heavy industrial floors get strong support from Type HD Form Deck. The durable design performs over the long term in demanding industrial settings.

Bridge and Highway Formwork

Bridge and Highway Formwork

Bridge and highway construction commonly uses Type HD Form Deck as permanent formwork, where it supports heavy concrete loads during placement and adds lasting strength.

Standards and product documentation

Type HD Form Deck is produced to SDI (Steel Deck Institute) specifications, which keeps design and performance standards high.

1" Type HD Form Deck questions

What is the main purpose of Type HD Form Deck?

It is permanent formwork for heavy-duty concrete slabs, such as industrial floors, bridges, and infrastructure projects. Wet concrete rests on it during placement, and it stays in place after curing.

What gauge choices does Type HD Form Deck offer?

26 GA, 24 GA, 22 GA, and 20 GA, so you can match various load capacities and project needs.

Will Type HD Form Deck need temporary shoring?

Possibly. Temporary shoring may be required during installation to bear the deck and wet concrete weight until the slab fully cures.

Which fastening methods are recommended for Type HD Form Deck?

Pins, powder-actuated fasteners, or TEK screws are typical. Sidelaps are secured with button punching or screws at 12" o.c.

Can Type HD Form Deck be cut to custom lengths?

Yes, anywhere from 6'-0" to 40'-0". Waste stays minimal and each project gets a precise fit.

Type BI Inverted Form Deck

Exposed-soffit architectural ceilings call for Type B Inverted Form Deck, which also acts as permanent formwork for concrete slabs in floor and roof systems. Gauges range from 22 GA through 16 GA. Schools, offices, and commercial facilities in Naples are among its common uses.

Dimensions and profile

Type BI Inverted Form Deck profile dimensions
Type BI Inverted Form Deck dimensions
PropertyDimension
Profile Depth1.5 inches
Coverage Width36 inches
Rib Spacing6 inches (center to center)
Rib Height1.5 inches

Type BI Inverted Form Deck has a 1.5-inch rib depth and a standard 36-inch coverage width. Ribs face upward when it is installed, so a smooth, flat soffit shows below and works as an architectural ceiling with no added finish. Rib spacing of 6 inches (center to center) keeps the structure sound and still accommodates concrete placement.

Gauges and thicknesses

Type BI Inverted Form Deck gauges
GaugeBare steel thickness (in)Weight (lbs/sq ft)Typical applications
220.02991.25Light-duty floors and ceilings.
200.03581.5Standard commercial floor systems.
180.04742.6Heavy-duty applications, parking structures.
160.05983.0Heavy load industrial floors.

Gauges 22, 20, 18, and 16 are offered for Type BI Inverted Form Deck. For standard commercial work, the lighter gauges (22 and 20) are a good fit. Parking structures and heavy industrial floor systems call for the added strength of gauges 18 and 16.

Finishes and coatings

Type BI Inverted Form Deck finishes
FinishDetails
Galvanized G60Zinc coating of 0.6 oz/ft². Recommended for general environments.
Galvanized G90Zinc coating of 0.9 oz/ft². Ideal for highly corrosive environments.
Prime-PaintedProvides a base coat for additional protection or paint adhesion.
Bare SteelUnfinished; typically for indoor use or controlled environments.

Type BI Inverted Form Deck is offered with galvanized (G60 and G90) and prime-painted finishes. The galvanized coatings protect against corrosion, with G90 extending that protection to highly corrosive environments. G60 and G90 finishes conform to ASTM A653 specifications.

Material and finish options

Specify Type BI Inverted Form Deck in high-strength steel with a corrosion-resistant galvanized finish that meets ANSI/SDI standards. Painted finishes are available for tailored aesthetics, and bare steel is available for custom applications. Durability and steady performance are the goals behind each finish.

Custom lengths

We cut deck from 6′-0″ for smaller projects up to 40′-0″ for larger constructions. Our custom length service follows your requirements to deliver an optimal fit with minimal waste, whatever the size of the job in Naples.

Type BI Inverted Form Deck features

Type BI Inverted Form Deck brings high structural strength, efficient formwork, and corrosion-resistant finishes to architectural ceilings, multi-level parking structures, and commercial floor systems that require exposed soffits.

High Structural Strength

It carries concrete and live loads, and the underside becomes an architecturally finished exposed ceiling.

Efficient Formwork

Because the deck stays in place as permanent formwork for concrete slabs, labor and construction time drop and temporary forms never need removing.

Corrosion Resistance

For lasting corrosion resistance in commercial environments, choose G60/G90 galvanized or prime-painted finishes.

Cost-Effective

By combining formwork with structural support, it lowers material and labor costs where ceilings are left exposed.

Compliance with Standards

Conforms to SDI and ANSI guidelines for quality and code compliance in all applications.

Versatile Options

Gauges from 22 to 16 GA and multiple finishes are available to meet varying load and architectural needs.

Installation and connections

Installation practices

  • Set the deck perpendicular to the supports with the ribs pointing upward.
  • Use pins, powder-actuated fasteners, or TEK screws to fasten at each support.
  • Lap sidelaps and secure them at 12" o.c. with button punching or screws.

Fasteners and attachments

  • Pins or powder-actuated fasteners secure the deck to supports
  • #10 TEK screws at 6" o.c. on edges
  • Sidelaps attached through button punching or #10 TEK screws at 12" o.c.

Confirm the profile, gauge, span, loads and connections against your project drawings and the applicable product load tables before ordering.

Applications

Industrial Flooring with Exposed Ceiling

Industrial Flooring with Exposed Ceiling

Strong support for industrial floor systems plus an architecturally finished exposed soffit, which suits schools, offices, and civic buildings.

Multi-Level Parking Structures

Multi-Level Parking Structures

A frequent choice for parking garages, giving permanent formwork and a clean exposed underside that cuts finishing costs.

Standards and product documentation

SDI (Steel Deck Institute) specifications and ANSI standards apply to Type BI Inverted Form Deck, which supports high standards of design and performance.

Type BI Inverted Form Deck questions

Which projects use Type BI inverted form deck?

It appears in architectural ceiling systems, multi-level parking structures, schools, offices, and facilities needing an attractive exposed soffit.

What is different about installing Type BI?

The deck is installed inverted, ribs up, so the flat side faces down as a finished ceiling surface and needs no added finishing materials.

What gauge options exist?

Gauges 22, 20, 18, and 16 GA cover a range of structural requirements.

What finish options are there?

Corrosion resistance comes from G60 and G90 galvanized finishes, and prime-painted finishes add protection.

Does Type BI come in custom lengths for Naples jobs?

Yes, from 6'-0" to 40'-0", so each project gets a precise fit with minimal waste.

Ordering made simple

Steel Deck for Naples construction

Start with your plans or a takeoff. We review the profile, gauge, quantities and lengths, help with shop drawings when you need them, and come back with pricing and a delivery plan for Naples.

Send your project requirements

Helpful details for an accurate quote

  • Product profile or series, dimensions, gauge and specified finish.
  • Required quantities, sheet or member lengths, and project drawings.
  • Project address in Naples, delivery date and site access requirements.
  • Any specified load tables, connection details or supporting documentation.

How We Work

We Guide You Through the Process

From manufacturing to delivery, we ensure precision, efficiency, and compliance with industry standards.

01
01

Takeoff and Shop Drawings Services

We provide specialized takeoff services for accurate quotations and detailed shop drawings to produce optimized cutting lists for sheets, ensuring efficient execution and waste-free outcomes in your projects.

02
02

Manufacture

We manufacture metal decks to SDI and ANSI standards, ensuring strength, durability, and compliance. We provide custom lengths and high-precision fabrication for optimized performance in roof, floor, and form deck applications.

03
03

Swift Deliveries & Nationwide Reach

While based in South Florida, we serve clients nationwide, ensuring quality, efficiency, and timely deliveries across the U.S., reflecting our commitment to excellence without boundaries.

Frequently Asked Questions

Where can I get steel deck in Naples?

Miami Metal Deck delivers to Naples with same-day pickup in Miami Gardens and 1-day delivery to most Florida cities. Call 305-760-2575.

Do you provide shop drawings?

Yes. We offer complete takeoff services, shop drawings, and optimized cutting lists for all steel deck orders.

What steel deck products does Miami Metal Deck sell?

Roof deck (Type B, Vented Type B, Type N), composite floor deck in several profiles, and form deck (Type S, HD, BI). Each is offered in various gauges and galvanized finishes.

Roof deck, composite deck, form deck: how do they differ?

Roof deck is built to support insulation and roofing systems. Composite deck bonds with poured concrete to make a load-bearing floor slab. Form deck is concrete formwork, temporary or permanent.

Which gauges and finishes are available?

Depending on the product type, we stock gauges 16 to 28. Galvanized finishes come in G60 and G90, and custom lengths run from 6 to 40 feet.

Do you help with takeoffs and shop drawings?

We do. Our engineering team offers specialized takeoff services, detailed shop drawings, and optimized cutting lists for accurate quotations and efficient project execution in Naples and elsewhere.

What standards do the products follow?

Steel deck products comply with ANSI/SDI standards (RD-2017 for roof deck, C-2017 for composite floor deck, NC-2017 for non-composite form deck), and we are a Steel Deck Institute member.

Phone

305 760 25 75

E-Mail

info@mmdeck.com

Address

16000 NW 49th Ave Suite A, Miami Gardens, FL 33014

Get a Free Quote